Japan Bioanalysis Forum 中村隆広 (株式会社新日本科学) Summary of the Draft Guideline on Bioanalytical Method (Ligand Binding Assay) Validation in Pharmaceutical Development http://bioanalysisforum.jp/ 医薬品開発における生体試料中薬物濃度分析法 (リガンド結合法)のバリデーションに関する カイドライン案の概要 Takahiro Nakamura, PhD, DJSOT (Shin Nippon Biomedical Laboratories, Ltd. , SNBL) 5th JBF Symposium, Draft BMV Guideline for LBA 1 http://bioanalysisforum.jp/ Japan Bioanalysis Forum 5th JBF Symposium, Draft BMV Guideline for LBA 2 Japan Bioanalysis Forum 1. Scope: リガンド結合法を用いて分析する低分子化合物も対象 The guideline also applies to low-molecular-weight drugs that are analyzed by LBAs. 2. Reference standard: 標準物質はその特性の精査が必要 It is necessary to show well-established characteristics of reference standard. 3. Full validation: 市販キットもフルバリデーションが必要 A full validation is required for a commercialized kit. 4. MRD: フルバリデーションの実施前にMRDを設定する. Determination of minimum required dilution (MRD) before a full validation. 5. Specificity: 特異性を評価する. Specificity should be evaluated. http://bioanalysisforum.jp/ Contents (1/2) 5th JBF Symposium, Draft BMV Guideline for LBA 3 Japan Bioanalysis Forum 6. Selectivity: 選択性の評価方法が低分子ガイドラインとは異なる. Evaluation method for selectivity differs from that of LMW. 7. Accuracy and precision: 真度及び精度は、定量上限のQC試料に ついても評価が必要であり、トータルエラーについても評価する. Accuracy and precision should be evaluated at ULOQ, and total error should be evaluated. 8. QCs: 高濃度のQC試料の濃度を定量上限の1/3以上とする. Concentration of high-level QC is at least 1/3 of ULOQ. 9. Dilutional linearity: 希釈直線性の評価が必要 Dilutional linearity should be evaluated. 10. Partial validation: 重要試薬のロット変更やMRDの変更時にパー シャルバリデーションが必要である. Partial validation should be performed after changing a critical reagent lot or MRD. http://bioanalysisforum.jp/ Contents (2/2) 5th JBF Symposium, Draft BMV Guideline for LBA 4 Japan Bioanalysis Forum http://bioanalysisforum.jp/ Guideline/Guidance Comparison on BMV for LBA 5th JBF Symposium, Draft BMV Guideline for LBA 5 Japan Bioanalysis Forum Scope in MHLW This guideline is applicable to the validation of analytical methods based on ligand binding assays (LBAs) to measure concentrations of drugs in biological samples obtained in toxicokinetic studies and clinical trials, as well as to the analyses of study samples using such methods. The information in this guideline generally applies to the quantification of peptides and proteins as well as lowmolecular-weight drugs that are analyzed by LBAs. A typical example of LBA is immunological assay based on antigen-antibody reaction, such as enzyme immunoassay (EIA). http://bioanalysisforum.jp/ 1. リガンド結合法を用いて分析する低分子化合物も対象 The guideline also applies to low-molecular-weight drugs that are analyzed by LBAs. (endogenous compounds) Analyte is the same as for endogenous compounds 5th JBF Symposium, Draft BMV Guideline for LBA 6 Japan Bioanalysis Forum Reference Standard MHLW Draft Guideline: A reference standard serves as the scale in quantifying an analyte, ……... A certificate of analysis or an alternative statement that provides information on lot number, content (amount, purity, or potency), storage conditions, and expiration date or re-test date should accompany the standard. As a reference standard, it is necessary to show its authenticated source and its characteristics should be well-established. 5th JBF Symposium, Draft BMV Guideline for LBA http://bioanalysisforum.jp/ 2. 標準物質はその特性の精査が必要 It is necessary to show well-established characteristics of reference standard. 7 Japan Bioanalysis Forum Reference Standard Macromolecules are heterogeneous and their potency and immunoreactivity may vary. The reference material should be well characterised and documented (e.g. certificate of analysis and origin).The purest reference standard available at the time should be procured. It is strongly recommended that the batch of the reference standard used for the preparation of calibration standards and QC samples is the same as used for dosing in the non clinical and clinical studies. In case of change of batch, an analytical characterisation and bioanalytical evaluation should be carried out prior to use to ensure that the performance characteristics of the method are not altered. 5th JBF Symposium, Draft BMV Guideline for LBA http://bioanalysisforum.jp/ EMA Guideline: 8 Japan Bioanalysis Forum Reference Standard A. Key Reagents Key reagents, such as reference standards, antibodies, tracers, and matrices should be characterized appropriately and stored under defined conditions. 5th JBF Symposium, Draft BMV Guideline for LBA http://bioanalysisforum.jp/ FDA Draft Guidance: 9 Japan Bioanalysis Forum Reference Standard MHLW Draft Guideline (intended): Structure, physico-chemical characterization, amount, purity, potency, immunological characterization, or etc. are well-established. It is not recommended that the batch of the reference standard used for calibration standards and QC samples is the same as used for dosing studies, or that an analytical characterisation and bioanalytical evaluation are carried in the case of change of batch of reference standard. 5th JBF Symposium, Draft BMV Guideline for LBA http://bioanalysisforum.jp/ Well-established characteristics of reference standard: 10 Japan Bioanalysis Forum Full Validation - Kits MHLW Draft Guideline: A full validation should be performed when establishing a new bioanalytical method for quantification of an analyte/analytes. A full validation is also required when implementing an analytical method that is disclosed in literature or commercialized as a kit product. http://bioanalysisforum.jp/ 3. 市販キットもフルバリデーションが必要 A full validation is required for a commercialized kit. An analytical method validation should be performed at every relevant facility. 5th JBF Symposium, Draft BMV Guideline for LBA 11 Japan Bioanalysis Forum Full Validation - Kits 7.1.1.13. Commercial kits Commercial kits may have been developed for purposes other than to support pharmacokinetics. Therefore, commercial kits need to be revalidated to ensure that the LLOQ and the QC samples in the actual concentration range to be used for sample analysis perform accurately and precisely. The principles of validation listed above apply. 5th JBF Symposium, Draft BMV Guideline for LBA http://bioanalysisforum.jp/ EMA Guideline: 12 Japan Bioanalysis Forum Full Validation - Kits C. Diagnostic Kits …….. Diagnostic kit validation data provided by the manufacturer may not ensure reliability of the kit method for drug development purposes. The performance of diagnostic kits should be assessed in the facility conducting the sample analysis. …….. 5th JBF Symposium, Draft BMV Guideline for LBA http://bioanalysisforum.jp/ FDA Draft Guidance: 13 Japan Bioanalysis Forum Full Validation – MRD MHLW Draft Guideline: In an LBA validation, full validation should be conducted using samples diluted at a factor of minimum required dilution (MRD), which has been determined in the course of method development. 5th JBF Symposium, Draft BMV Guideline for LBA http://bioanalysisforum.jp/ 4. フルバリデーションの実施前にMRDを設定する Determination of minimum required dilution (MRD) before a full validation. 14 Japan Bioanalysis Forum MRD Different dilution fold ↓ Standard curve changes ↓ Analysis with the same dilution fold Determination of MRD http://bioanalysisforum.jp/ Response 10% Serum(10-fold dilution) 20% Serum(5-fold dilution) 33% Serum(3-fold dilution) 50% Serum(2-fold dilution) Analysis with the same dilution fold for calibration standards, QCs, and samples Concentration (log) 5th JBF Symposium, Draft BMV Guideline for LBA 15 Japan Bioanalysis Forum Full Validation – MRD MHLW Draft Guideline: Glossary: Minimum required dilution (MRD): A dilution factor of samples (including calibration standards and QC samples) with buffer to analyze samples appropriately. MRD should be identical for all samples. It may not necessarily be the exact minimum dilution where samples can be analyzed. 5th JBF Symposium, Draft BMV Guideline for LBA http://bioanalysisforum.jp/ 4. フルバリデーションの実施前にMRDを設定する Determination of minimum required dilution (MRD) before a full validation. 16 Japan Bioanalysis Forum Full Validation – MRD 7.1.1.6. Minimum required dilution Because matrices may exhibit a high background signal, it may be necessary to determine the minimum required dilution. The minimum required dilution is the smallest dilution to which a sample must be diluted in buffer to optimize accuracy and precision in an assay run by reducing the signal to noise ratio. Spiked samples should be prepared in the same matrix as the study samples for determination of the minimum required dilution. http://bioanalysisforum.jp/ EMA Guideline: FDA Draft Guidance: No statement 5th JBF Symposium, Draft BMV Guideline for LBA 17 Japan Bioanalysis Forum Full Validation - Specificity 5. 特異性を評価する Specificity should be evaluated. Specificity is the ability of an analytical method to detect and differentiate the analyte from other substances such as its related substances. For LBA, it is important that binding reagent specifically binds to the target analyte but does not cross-react with coexisting substances that are structurally similar to the analyte. If similar substances are expected to be present in biological samples of interest, the extent of the impact of such substances on the analysis of analyte should be evaluated. It is acceptable that specificity is evaluated in the course of method development or after completing a method validation. http://bioanalysisforum.jp/ MHLW Draft Guideline: Analyte: anti-X human IgG Sensitivity: ~1 ng/mL in matrix Matrix: ~10 mg/mL IgG in human serum 5th JBF Symposium, Draft BMV Guideline for LBA 18 Japan Bioanalysis Forum Full Validation - Specificity 7.1.1.2. Specificity Specificity of the binding reagent(s) refer(s) to its (their) ability to bind solely to the analyte of interest. Specificity is related to the concept of cross-reactivity. Ideally the binding reagent should be specific such that no cross-reactivity occurs with structurally “related compounds” (e.g. endogenous compounds, isoforms, variants forms of the analyte, or physico-chemically similar compounds) or with anticipated concomitant medication. During method development and validation, frequently these “related molecules” are not available. Evaluation of specificity may be conducted after the original validation is completed as more data on the behaviour of the analyte become available. …….. 5th JBF Symposium, Draft BMV Guideline for LBA http://bioanalysisforum.jp/ EMA Guideline: 19 Japan Bioanalysis Forum Full Validation - Specificity VIII. GLOSSARY Selectivity/Specificity: The ability of the bioanalytical method to measure and differentiate the analytes in the presence of components that may be expected to be present. These could include metabolites, impurities, degradants, or matrix components. http://bioanalysisforum.jp/ FDA Draft Guidance: No statement in LBA section To see selectivity section 5th JBF Symposium, Draft BMV Guideline for LBA 20 Japan Bioanalysis Forum Full Validation - Selectivity MHLW Draft Guideline: Selectivity is the ability of an analytical method to measure and differentiate the analyte in the presence of other components in samples. Selectivity is evaluated using blank samples obtained from at least 10 individual sources and near-LLOQ QC samples prepared from individual blank samples. In case of a matrix with limited availability, it is acceptable to use matrix samples obtained from less than 10 sources. Assay results for at least 80% of the blank samples should be below the LLOQ, and accuracy of the measurements of at least 80% of the nearLLOQ QC samples should be within ±20% of the theoretical concentration (or ±25% at the LLOQ). 5th JBF Symposium, Draft BMV Guideline for LBA http://bioanalysisforum.jp/ 6. 選択性の評価方法が低分子ガイドラインとは異なる Evaluation method for selectivity differs from that of LMW. 21 Japan Bioanalysis Forum Full Validation - Selectivity 2 LLOQ 定量下限 1 0 1 2 3 Response (Conc.) 5 ±25% ±25% Blank ブランク 添加試料 LLOQ QC sample レスポ ンス 1 (濃度) 4 6 ブランク試料が定量下限(1.0)の20%未満 Response of blank sample is less than 20% LC-MS 低分子・LC 2 http://bioanalysisforum.jp/ Response レ ス ポ ン ス LLOQ 定量下限 0 1 LBA LBA 2 3 4 5 6 7 8 9 10 At least 80% of the blank samples should be below the LLOQ ブランク試料の80%以上が定量下限(1.0)未満 At least 80% of the LLOQ QC samples should be within ±25% LLOQ添加試料の80%以上の真度が25%以内 5th JBF Symposium, Draft BMV Guideline for LBA 22 Japan Bioanalysis Forum Full Validation - Selectivity 7.1.1.3. Selectivity (1/2) Selectivity of a ligand-binding assay is the ability to measure the analyte of interest in the presence of unrelated compounds in the matrix. Generally there is no extraction due to the inherent characteristics of macromolecules. Then, unrelated compounds present in matrix e.g. degrading enzymes, heterophilic antibodies or rheumatoid factor, may interfere with the analyte of interest in the ligand binding assay. Selectivity is tested by spiking at least 10 sources of sample matrix at or near the LLOQ. These sources should include lipemic and haemolysed samples. ………. 5th JBF Symposium, Draft BMV Guideline for LBA http://bioanalysisforum.jp/ EMA Guideline: 23 Japan Bioanalysis Forum Full Validation - Selectivity 7.1.1.3. Selectivity (2/2) …….. It is also strongly recommended that sources from relevant disease population be included. Selectivity should be evaluated at the low end of an assay where problems occur in most cases. It may be prudent also to evaluate selectivity at higher analyte concentrations. In cases where interference is concentration dependent, it is essential to determine the minimum concentration where interference occurs. It may be necessary to adjust the lower level of quantification accordingly, before assay validation. The accuracy should be within 20% (25% at the LLOQ) of the nominal spiked concentration in at least 80% of the matrices evaluated. 5th JBF Symposium, Draft BMV Guideline for LBA http://bioanalysisforum.jp/ EMA Guideline: 24 Japan Bioanalysis Forum Full Validation - Selectivity FDA Draft Guidance: As with chromatographic methods (described in Section III), LBAs should be shown to be selective for the analyte. The following recommendations for dealing with two selectivity issues should be considered: a. Interference from Substances Physiochemically Similar to the Analyte Cross-reactivity of metabolites, concomitant medications, and their significant metabolites, or endogenous compounds should be evaluated individually and in combination with the analyte of interest. …… 5th JBF Symposium, Draft BMV Guideline for LBA http://bioanalysisforum.jp/ 1. Selectivity (1/2) 25 Japan Bioanalysis Forum Full Validation - Selectivity 1. Selectivity (2/2) …… b. Matrix Effects Matrix effects should be evaluated. For example: The calibration curve in biological fluids should be compared with calibrators in buffer to detect matrix effects using at least ten sources of blank matrix. 5th JBF Symposium, Draft BMV Guideline for LBA http://bioanalysisforum.jp/ FDA Draft Guidance: 26 Japan Bioanalysis Forum Full Validation - Calibration Curve 4.1.3. Calibration Curve A calibration curve demonstrates the relationship between a theoretical concentration and a response variable for an analyte. A calibration curve should be prepared using the same matrix as the intended study samples, whenever possible, by spiking the blank matrix with known concentrations of the analyte. A calibration curve should be generated with at least 6 concentration levels of calibration standards, including LLOQ and ULOQ samples, and a blank sample. Anchor point samples at concentrations below LLOQ and above ULOQ may also be used to improve curve fitting. A 4- or 5-parameter logistic model is generally used for the regression equation of calibration curve. The validation report should include the regression equation and weighting conditions used. 5th JBF Symposium, Draft BMV Guideline for LBA http://bioanalysisforum.jp/ MHLW Draft Guideline: 27 Japan Bioanalysis Forum http://bioanalysisforum.jp/ Full Validation - Calibration Curve 5th JBF Symposium, Draft BMV Guideline for LBA 28 Japan Bioanalysis Forum Full Validation - Calibration Curve ●: Calibration standards ● ULOQ Response ● ● ● ● LLOQ http://bioanalysisforum.jp/ ● ● ● Concentration (log) 5th JBF Symposium, Draft BMV Guideline for LBA 29 Japan Bioanalysis Forum Full Validation - Calibration Curve ● ◎: Anchor points ● ◎ ULOQ Response ● ● ● 4-parameter logistic model ● LLOQ http://bioanalysisforum.jp/ ●: Calibration standards ● ● ◎ Concentration (log) 5th JBF Symposium, Draft BMV Guideline for LBA 30 Japan Bioanalysis Forum Full Validation - Calibration Curve MHLW and EMA: Accuracy*: within ±25% →FDA: within ±20% ● ◎: Anchor points ● *: Back-calculated concentrations ◎ ULOQ Response ● MHLW, EMA, FDA: At least 75% of calibration standards meet the criteria ● ● 4-parameter logistic model Accuracy*: within ±20% ● LLOQ ● ● ◎ http://bioanalysisforum.jp/ ●: Calibration standards Accuracy*: within ±25% Concentration (log) 5th JBF Symposium, Draft BMV Guideline for LBA 31 Japan Bioanalysis Forum Full Validation - Calibration Curve MHLW and EMA: Accuracy*: within ±25% →FDA: within ±20% ● ◎: Anchor points ● *: Back-calculated concentrations Response **: relative error 4-parameter logistic model Accuracy*: within ±20% FDA: Total error: not exceed 30% (MHLW, EMA: No statement in calibration curve section) ● ● ● ◎ Total error: a sum of absolute accuracy (-100%)** and precision ● ● LLOQ ULOQ ● MHLW, EMA, FDA: At least 75% of calibration standards meet the criteria ◎ http://bioanalysisforum.jp/ ●: Calibration standards Accuracy*: within ±25% Concentration (log) 5th JBF Symposium, Draft BMV Guideline for LBA 32 Japan Bioanalysis Forum Total Error ......... .. RE CV .......... .. ......... . . .... . . .. ..... .... ..... . . . . http://bioanalysisforum.jp/ Total error = |RE| + CV Modified from B. DeSilva et al., Pharm. Res., 20: 1885-1900 (2003) 5th JBF Symposium, Draft BMV Guideline for LBA 33 Japan Bioanalysis Forum 7. 真度及び精度は、定量上限のQC試料についても評価が必要 であり、トータルエラーについても評価する Accuracy and precision should be evaluated in ULOQ, and total error should be evaluated. MHLW Draft Guideline: Accuracy of an analytical method describes the degree of closeness between analyte concentration determined by the method and its theoretical concentration. Precision of an analytical method describes variation between individual concentrations determined in repeated measurements. …….. 5th JBF Symposium, Draft BMV Guideline for LBA http://bioanalysisforum.jp/ Full Validation – Accuracy & Precision 34 Japan Bioanalysis Forum http://bioanalysisforum.jp/ Full Validation – Accuracy & Precision 5th JBF Symposium, Draft BMV Guideline for LBA 35 Japan Bioanalysis Forum Full Validation - QCs ● ◎: Anchor points ● ◎ ULOQ Response ● ● ● ● LLOQ http://bioanalysisforum.jp/ ●: Calibration standards ● ● ◎ Concentration (log) 5th JBF Symposium, Draft BMV Guideline for LBA 36 Japan Bioanalysis Forum Full Validation - QCs ●: Calibration standards ● ◎: Anchor points Response ● ● ULOQ HQC ● ● ● MQC ● http://bioanalysisforum.jp/ ● ◎ ● LLOQ ● LQC ● ◎ Concentration (log) 5th JBF Symposium, Draft BMV Guideline for LBA 37 Japan Bioanalysis Forum Full Validation - QCs ◎: Anchor points ● Response ● ● ULOQ HQC ● ● ● MQC Accuracy: within ±20% Precision: not exceed 20% ● ● LLOQ ● ● ◎ http://bioanalysisforum.jp/ ●: Calibration standards FDA: MHLW and EMA: → Accuracy: within ±20% Accuracy: within ±25% Precision: not exceed 20% Precision: not exceed 25% ◎ ● LQC Accuracy: within ±25% Precision: not exceed 25% Concentration (log) 5th JBF Symposium, Draft BMV Guideline for LBA 38 Japan Bioanalysis Forum Full Validation - QCs ◎: Anchor points MHLW, EMA: Total error: not exceed 40% ● Response ● ● ULOQ HQC ● ● ● MQC Accuracy: within ±20% Precision: not exceed 20% MHLW, EMA: Total error: not exceed 40% ● ● LLOQ ● ● ◎ LQC MHLW, EMA: Total error: not exceed 30% (FDA: No statement in QC section) http://bioanalysisforum.jp/ ●: Calibration standards FDA: MHLW and EMA: → Accuracy: within ±20% Accuracy: within ±25% Precision: not exceed 20% Precision: not exceed 25% ◎ ● Accuracy: within ±25% Precision: not exceed 25% Concentration (log) 5th JBF Symposium, Draft BMV Guideline for LBA 39 Japan Bioanalysis Forum Full Validation – Accuracy & Precision MHLW Draft Guideline: …….. The low-level should be within 3 times the LLOQ, the mid-level is around the midpoint on the calibration curve, and the high-level should be at least one-third of the ULOQ of the calibration curve. Within-run and between-run accuracy and precision should be evaluated by repeating the analysis run at least 6 times. 5th JBF Symposium, Draft BMV Guideline for LBA http://bioanalysisforum.jp/ 8. 高濃度のQC試料の濃度を定量上限の1/3以上とする Concentration of high-level QC is at least 1/3 of ULOQ. 40 Japan Bioanalysis Forum Full Validation - QCs ● ◎: Anchor points HQC ● Response ● ● ◎ ULOQ x1/3 ● MQC ● 3x ● ● http://bioanalysisforum.jp/ ●: Calibration standards ● LLOQ ● LQC ● ◎ 3x Concentration (log) 5th JBF Symposium, Draft BMV Guideline for LBA 41 Japan Bioanalysis Forum Full Validation – Accuracy & Precision 7.1.1.8. Precision and accuracy For the estimation of precision and accuracy QC samples should not be freshly prepared, but should be frozen and treated the same way as for the analysis of study samples. At least 5 QC samples (anticipated LLOQ, less than 3 times the LLOQ, mid, high and anticipated ULOQ) should be used to assess accuracy, precision and the total error of the method. …….. 5th JBF Symposium, Draft BMV Guideline for LBA http://bioanalysisforum.jp/ EMA Guideline: 42 Japan Bioanalysis Forum Full Validation – Accuracy & Precision FDA Draft Guidance: Accuracy is determined by replicate analysis of samples containing known amounts of the analyte (QCs). Accuracy should be measured using a minimum of five determinations per concentration. A minimum of three concentrations in the range of expected study sample concentrations is recommended. The mean value should be within 20% of the actual value except at LLOQ, where it should not deviate by more than 25%. …… 5th JBF Symposium, Draft BMV Guideline for LBA http://bioanalysisforum.jp/ 2. Accuracy, Precision and Recovery 43 Japan Bioanalysis Forum Full Validation – Dilutional Linearity 9. 希釈直線性の評価が必要 Dilutional linearity should be evaluated. 4.1.5. Dilutional linearity http://bioanalysisforum.jp/ MHLW Draft Guideline: Dilutional linearity is assessed to confirm that the method can appropriately analyze samples at concentrations exceeding the ULOQ without influence of a hook effect or prozone effect and that these measurements are not affected by dilution within the calibration range. Dilutional linearity is evaluated by analyzing a QC sample exceeding the ULOQ and its serially-diluted samples at multiple concentrations. The absence or presence of response reduction (hook effect or prozone effect) is checked in the analyzed samples, and measures should be taken to eliminate response reduction in study sample analysis, when applicable. Accuracy and precision in the measurements corrected for the dilution factor should be within ±20% deviation of the theoretical concentration and not more than 20%, respectively. 5th JBF Symposium, Draft BMV Guideline for LBA 44 Japan Bioanalysis Forum Full ValidationData – Dilutional Linearity 1 Hook effect Prozone OD450 1.0 0.5 0.0 0.1 1 10 100 http://bioanalysisforum.jp/ 1.5 1000 Drug (ng/ml) Modified from B. DeSilva et al., Pharm. Res., 20: 1885-1900 (2003) 5th JBF Symposium, Draft BMV Guideline for LBA 45 Japan Bioanalysis Forum Nominal conc. Measured conc. Dilution (ng/mL) (ng/mL) 100000 1 >ULOQ 1000 1 >ULOQ 100 1 >ULOQ 40.0 5000 42.54 20.0 10000 18.51 10.0 20000 9.76 5.00 40000 5.34 2.50 80000 2.48 1.25 160000 1.23 Mean Ref. standard:200000 ng/mL SD ULOQ: 50 ng/mL %CV Final conc. (ng/mL) >ULOQ >ULOQ >ULOQ 212700 185100 195200 213600 198400 196800 200300 10987 5.5 5th JBF Symposium, Draft BMV Guideline for LBA Accuracy (%) 106.4 92.6 97.6 106.8 99.2 98.4 http://bioanalysisforum.jp/ Full Validation – Dilutional Linearity 46 Japan Bioanalysis Forum Full Validation – Dilutional Linearity 7.1.1.9. Dilutional linearity Because the narrow range of the calibration standard curve, it is necessary to demonstrate with QC samples that the analyte of interest, when present in concentrations exceeding the range of quantification (above ULOQ), can be accurately measured by the assay after dilution in blank matrix to bring the analyte concentrations into the validated range for analysis. An additional reason for conducting dilutional experiments is to detect a possible prozone or “hook effect” i.e. a signal suppression caused by high concentrations of analyte. The backcalculated concentration for each dilution should be within 20% of the nominal concentration after correction for dilution and the precision of the final concentrations across all the dilutions should not exceed 20%. 5th JBF Symposium, Draft BMV Guideline for LBA http://bioanalysisforum.jp/ EMA Guideline: 47 Japan Bioanalysis Forum Full Validation – Dilutional Linearity FDA Draft Guidance: ……. Samples with concentrations over the ULOQ should be diluted with the same matrix as used for the study samples, and accuracy and precision should be demonstrated. …… 5th JBF Symposium, Draft BMV Guideline for LBA http://bioanalysisforum.jp/ 2. Accuracy, Precision and Recovery 48 Japan Bioanalysis Forum Critical reagent MHLW Draft Guideline: 重要試薬とは,リガンド結合法による生体試料中薬物濃度分析におい て分析結果に直接影響する試薬を指し,主に結合試薬(抗体及びその 標識体等)が該当する. ….. 6. Points to note 6.5. Critical reagent Critical reagents are usually binding reagents (labeled or unlabeled antibodies) that have a direct impact on the results of ligand-binding-based bioanalytical methods. ….. 5th JBF Symposium, Draft BMV Guideline for LBA http://bioanalysisforum.jp/ 6. 注意事項 6.5. 重要試薬 49 Japan Bioanalysis Forum Critical reagent 6. 注意事項 6.5. 重要試薬 ….. 重要試薬のロット変更の際には原則としてパーシャルバリデー ションが必要である. 6. Points to note 6.5. Critical reagent ….. Partial validation is required when the critical reagent lot is changed in principle. 5th JBF Symposium, Draft BMV Guideline for LBA http://bioanalysisforum.jp/ MHLW Draft Guideline: 50 Japan Bioanalysis Forum 10. 重要試薬のロット変更やMRDの変更時にパーシャルバリデーション が必要である Partial validation should be performed after changing a critical reagent lot or MRD. (in principle) MHLW Draft Guideline: …….. Typical bioanalytical method changes subject to a partial validation are as follows: analytical method transfers between laboratories, changes in analytical instruments, changes of the critical reagent lot, changes in calibration range, changes in MRD, changes in anticoagulant, changes in analytical conditions, changes in sample storage conditions, confirmation of impact by concomitant drugs, and use of rare matrices. …….. 5th JBF Symposium, Draft BMV Guideline for LBA http://bioanalysisforum.jp/ Partial Validation 51 Japan Bioanalysis Forum Partial Validation 7.1.1.12. Reagents Critical reagents, including binding reagents (e.g. binding proteins, aptamers, antibodies or conjugated antibodies) and those containing enzymatic moieties have direct impact on the results of the assay and therefore their quality must be assured. Accordingly, when changing reagent batches during validation or sample analysis the analytical performance of the method must be verified to ensure that it is not altered compared with the original or previous batch. 5th JBF Symposium, Draft BMV Guideline for LBA http://bioanalysisforum.jp/ EMA Guideline: No statement about MRD 52 Japan Bioanalysis Forum Partial Validation FDA Draft Guidance: II. BACKGROUND Partial Validation Partial validations evaluate modifications of already validated bioanalytical methods. Partial validation can range from as little as one intra-assay accuracy and precision determination to a nearly full validation. Typical bioanalytical method modifications or changes that fall into this category include but are not limited to: …… 5th JBF Symposium, Draft BMV Guideline for LBA http://bioanalysisforum.jp/ No statement about critical reagent or MRD 53 Japan Bioanalysis Forum http://bioanalysisforum.jp/ Analysis of Study Samples 5th JBF Symposium, Draft BMV Guideline for LBA 54 Japan Bioanalysis Forum Analysis of Study Samples Incurred sample reanalysis (ISR) within ±30% for at least two-thirds of the samples analyzed in ISR. EMA Guideline: The concentration obtained for the initial analysis and the concentration obtained by reanalysis should be within 30% of their mean for at least 67% of the repeats. http://bioanalysisforum.jp/ MHLW Draft Guideline: The assay variability should be FDA Draft Guidance: Two-thirds (67%) of the repeated sample results should be within 20% for small molecules and 30% for large molecules. 5th JBF Symposium, Draft BMV Guideline for LBA 55 Japan Bioanalysis Forum Analysis of Study Samples Incurred sample reanalysis (ISR) Less than 1000 samples, approximately 10% samples Exceeding 1000 samples, approximately 5% samples EMA Guideline: Approximately 10% samples, less than 1000 samples Approximately 5% samples, exceeding 1000 samples FDA Draft Guidance: http://bioanalysisforum.jp/ MHLW Draft Guideline: The total number of ISR samples should be 7% of the study sample size. 5th JBF Symposium, Draft BMV Guideline for LBA 56 Japan Bioanalysis Forum Parallelism EMA Guideline: 7.1.1.10. Parallelism If study samples are available, parallelism between the calibration standard curve and serially diluted study samples should be assessed to detect possible matrix effect or differing affinities for metabolites. …….. FDA Draft Guidance: 1. Selectivity b. Matrix Effects http://bioanalysisforum.jp/ MHLW Draft Guideline: No statement Parallelism of diluted study samples should be evaluated with diluted standards to detect matrix effects. 5th JBF Symposium, Draft BMV Guideline for LBA 57 Japan Bioanalysis Forum Parallelism Standard v Serum Sample 1.56 100 25 6.25 Log (Dilution) Log (OD) Log (OD) Standard Serum Sample v 1.56 http://bioanalysisforum.jp/ Non-Parallel Case Parallel Case 100 25 6.25 Log (Dilution) Modified from Plikaytis et al. J. Clin. Microbiol. 32: 2441-2447 (1994) 5th JBF Symposium, Draft BMV Guideline for LBA 58 Japan Bioanalysis Forum 1. The guideline also applies to low-molecular-weight (LMW) drugs that are analyzed by LBAs. (endogenous compounds) 2. It is necessary to show well-established characteristics of reference standard. 3. A full validation is required for a commercialized kit. 4. Determination of minimum required dilution (MRD) before a full validation. 5. Specificity should be evaluated. 6. Evaluation method for selectivity differs from that of LMW. 7. Accuracy and precision should be evaluated in ULOQ, and total error should be evaluated. 8. Concentration of high-level QC is at least 1/3 of ULOQ. 9. Dilutional linearity should be evaluated. 10. Partial validation should be performed after changing a critical reagent lot or MRD. (in principle) 5th JBF Symposium, Draft BMV Guideline for LBA http://bioanalysisforum.jp/ Summary 59 Japan Bioanalysis Forum Ministry of Health, Labour and Welfare <MHLW>: Toshinari Mitsuoka National Institute of Health Sciences <NIHS>: Akiko Ishii, Noriko Katori, Haruhiro Okuda, Nana Kawasaki, Shingo Niimi Japan Pharmaceutical Manufacturers Association <JPMA>: Masataka Katashima (Astellas Pharma) Kotaro Maekawa (Hisamitsu Pharmaceutical) Japan Bioanalysis Forum <JBF>: All Steering Committee members, and LBA Task Force members 5th JBF Symposium, Draft BMV Guideline for LBA http://bioanalysisforum.jp/ Acknowledgements 60
© Copyright 2024