• Locations subject to temperatures or humidity outside the range specified in the specifications • Locations subject to condensation as the result of severe changes in temperature • Locations subject to corrosive or flammable gases • Locations subject to dust (especially iron dust) or salts • Locations subject to exposure to water, oil, or chemicals • Locations subject to shock or vibration • Take appropriate and sufficient countermeasures when installing systems in the following locations: • Locations subject to static electricity or other forms of noise • Locations subject to strong electromagnetic fields • Locations subject to possible exposure to radioactivity • Locations close to power supplies • Never use volatile solvents, such as benzene or thinners, or chemical dusters. Otherwise the Unit may malfunction. DRT2-ID32B/ID32B-1 DRT2-ID32BV/ID32BV-1 DRT2-OD32B/OD32B-1 DRT2-OD32BV/OD32BV-1 DRT2-MD32B/MD32B-1 DRT2-MD32BV/MD32BV-1 Remote I/O Terminals INSTRUCTION SHEET • Separate communications power lines from power lines used for driving loads. Specifications Thank you for purchasing this OMRON product. Please read this instruction sheet and thoroughly familiarize yourself with the functions and characteristics of the product before use. Please retain this sheet for future reference. Ratings To ensure safe operation, please also read the following manuals: DeviceNet Operation Manual (W267) DRT2-series DeviceNet Slaves Operation Manual (W404) • Output Terminals: DRT2-OD32B/OD32B-1 DRT2-OD32BV/OD32BV-1 • I/O Terminals: 1632665-2B General Precautions You must allow sufficient leeway in ratings and performance and provide proper fail-safe and other safety measures when using the Unit in any of the following applications. Be sure also to consult with your OMRON representative before actually attempting any of these applications. • Applications under conditions or environments not specified in the relevant manuals. • Applications for nuclear reactor control, train facilities, aviation facilities, motorized vehicles, furnaces, medical equipment, amusement equipment, and safety equipment. • Applications strongly related to human life or property, particularly those requiring safety. Safety Precautions Definition of Precautionary Information ! WARNING ! Caution Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury, or property damage. Warnings ! WARNING ! Caution Do not attempt to take the Unit apart and do not touch any internal parts while the power is being supplied. Doing either of these may result in electric shock. DRT2-MD32B/MD32B-1 DRT2-MD32BV/MD32BV-1 Application Precautions • Do not attempt to disassemble, repair, or modify the Units in any way. Doing so may result in electric shock. • Always turn OFF the power supply before attempting either of the following. Not turning OFF the power supply may result in malfunction or electric shock. • Connecting or wiring the cables • Connecting or disconnecting the connectors • Do not drop the product or subject it to excessive shocks or vibrations. Doing so may result in malfunction. • Separate communications cables from power lines or high-voltage lines. • Do not pull on the cables or bend the cables beyond their natural limit. Doing either of these may break the cables. • Fail-safe measures must be taken by the customer to ensure safety in the event of incorrect, missing, or abnormal signals caused by broken signal lines, momentary power interruptions, or other causes. Failing to take appropriate measures may result in injury. • Double-check all the wiring before turning ON the power supply. Incorrect wiring may result in burning. • Pay attention to the terminal polarity and voltage ranges for I/O connections when wiring the communications lines and power supply lines. Not doing so may result in malfunction. • Always use the power supply voltage specified in this document. An incorrect voltage may result in malfunction or burning. • Take appropriate measures to ensure that the specified power with the rated voltage and frequency is supplied in places where the power supply is unstable. An incorrect power supply may result in malfunction. • Before touching the board, be sure to first touch a grounded metallic object in order to discharge any static built-up. Not doing so may result in malfunction or damage. • When wiring the MIL Board Terminal, take countermeasures to prevent wiring cuttings from coming into contact with the product, such as covering the whole product with a dustproof cover. If wiring cuttings adhere to the PCB or circuit elements, they may cause short-circuiting. • When transporting or storing the MIL Board Terminal, cover the circuit board in antistatic material to protect it from static electricity and maintain the proper storage temperature. • When transporting the MIL Board Terminal, always pack it in the box specially designed for it, and do not subject it to excessive vibration or shock during transportation. Also, do not drop the MIL Board Terminal. • Do not touch the MIL Board Terminal or the components mounted to it with your bare hands. There are sharp leads and other parts on the board that may cause injury if handled improperly. Operating Environment Precautions • Install the Unit properly as specified in the relevant manuals. Improper installation of the Unit may result in malfunction. OD32B/OD32B-1 OD32BV/OD32BV-1 MD32B/MD32B-1 MD32BV/MD32BV-1 110 mA max. 120 mA max. 11 to 25 VDC I/O power supply voltage 20.4 to 26.4 VDC Communications power supply current consumption 100 mA max. Ambient operating temperature –10 to 55°C Ambient operating humidity 25% to 85% (with no condensation) Storage temperature –25 to 65°C Storage humidity 25% to 85% (with no condensation) Installation In-panel installation (M4 Screw mounting) Weight 50 g max. Input Specifications Item ID32B/ ID32BV MD32B/ MD32BV ID32B-1/ ID32BV-1 MD32B-1/ MD32BV-1 ON voltage 17 VDC min. (between each input terminal and V terminal) 17 VDC min. (between each input terminal and G terminal) OFF voltage 5 VDC min. (between each input terminal and V terminal) 5 VDC min. (between each input terminal and G terminal) OFF current 1.0 mA max. Input current 6.0 mA max. at 24 VDC 3.0 mA min. at 17 VDC (between each input terminal and V terminal) ON delay time 1.5 ms max. OFF delay time 1.5 ms max. Number of circuits 32 points/common, 1 common circuit 6.0 mA max. at 24 VDC 3.0 mA min. at 17 VDC (between each input terminal and G terminal) 16 points/common, 1 common circuit 32 points/common, 1 common circuit 16 points/common, 1 common circuit OD32B/ OD32BV MD32B/ MD32BV OD32B-1/ OD32BV-1 MD32B-1/ MD32BV-1 Output current 0.3 A/point 4A/common (See notes 1 and 3.) 0.3 A/point 2A/common (See notes 2 and 3.) 0.3 A/point 4A/common (See notes 1 and 3.) 0.3 A/point 2A/common (See notes 1 and 3.) Residual voltage 1.2 V max. (0.3 A DC between each output terminal and G terminal) 1.2 V max. (0.3 A DC between each output terminal and V terminal) Leakage current 0.1 mA max. (24 VDC between each output terminal and G terminal) 0.1 mA max. (24 VDC between each output terminal and V terminal) ON delay time 0.5 ms max. • Output Specifications Item • Tighten all product mounting screws to the specified torque. • Keep within the specified ranges when performing wiring for communications. Incorrect wiring may result in burning. ID32B/ID32B-1 ID32BV/ID32BV-1 Communications power supply voltage Make sure that communications connector screws are tightened to a torque of 0.5 to 0.6 N⋅m. Incorrect tightening torque may result in malfunction. • Do not install the Unit in the following places: • Locations subject to direct sunlight DRT2-ID32B/ID32B-1 DRT2-ID32BV/ID32BV-1 Item OMRON Corporation EOMRON Corporation 2004 – 2012 All Rights Reserved • Input Terminals: OFF delay time 1.5 ms max. Number of circuits 32 points/common, 1 common circuit Note 1. 2. 3. 16 points/common, 1 common circuit 32 points/common, 1 common circuit The total of the external load currents must not exceed 4A. The total of the external load currents must not exceed 2A. The V or G terminal current must not exceed 1 A per terminal. External Dimension DRT2-jjj32B(-1) DRT2-jjj32BV(-1) 16 points/common, 1 common circuit Nomenclature DRT2-OD32B/OD32BV (NPN) DRT2-jjj32BV(-1) DRT2-jjj32B(-1) DeviceNet communications connector DeviceNet communications connector Node address switches Node address switches DeviceNet operation indicators DeviceNet operation indicators I/O operation indicators Board mounting holes 24 VDC I/O operation indicators Board mounting holes Board mounting holes DRT2-OD32B-1/OD32BV-1 (PNP) I/O connector I/O connector (MIL) Rotary Switch Setting Note 1. 2. Factory setting: 00 If the address is set to 64 or higher, the node address set from the Configurator will be used. Indicators The meanings of the MS and NS indicators are given in the following table. Indicator Color Status Meaning MS Green Lit Normal operation MS Green Flashing Not set MS Red Lit Fatal error Flashing Non–fatal error --- Not lit No power supply Green Lit Online/communications connection established Flashing Online/communications connection not established Lit Fatal communications error Flashing Non-fatal communications error --- Not lit Offline/power supply OFF Yellow Lit Input signal ON Not lit Input signal OFF NS Red I/O DRT2-MD32B/MD32BV (NPN) DRT2-MD32B-1/MD32BV-1 (PNP) Mounting and Mounting Dimensions Mounting Dimensions Mounting Use screws to mount the MIL Board Terminal in the Control Panel. MIL Board Terminals cannot be mounted on DIN Track. Drill the mounting holes in the control panel according to the mounting dimensions and secure the Terminal with M4 screws using spacers. The appropriate tightening torque is 0.6 to 0.8 NSm. The MIL Board Terminal can be mounted in any direction. Four, 4.5 dia. or M4 Wiring DC-DC converter (Not isolated) Physical layer Internal circuits Communications connector • Communications Circuit Configuration and External Wiring This equipment is suitable for use in Class I, Div. 2, Group A, B, C, D or Non-Hazardous Location Only. WARNING – Explosion Hazard – Substitution of Components May Impair Suitability For Class I, Div. 2. WARNING – Explosion Hazard – Do not Disconnect Equipment Unless Power Has Been Switched Off Or The Area Is Known To Be Non-Hazardous. • I/O Configuration and External Wiring DRT2-ID32B/ID32BV (NPN) OMRON Corporation Industrial Automation Company Tokyo, JAPAN DRT2-ID32B-1/ID32BV-1 (PNP) Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V.Wegalaan 67–69, NL–2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300 Fax: (31)2356-81-388 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL 60173–5302 U.S.A. Tel: (1) 847–843–7900 Fax: (1) 847–843–7787 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05–05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835–3011 Fax: (65) 6835–2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, Pu Dong New Area, Shanghai, 200120, China Tel: (86) 21–5037–2222 Fax: (86) 21–5037–2200 Note: Specifications subject to change without notice. Printed in China (18)ボードを輸送するときは、専用の梱包箱を使用してください。また、輸 送中に過度な振動や衝撃が加わらないよう、また製品の落下などがない ように注意してください。 (19)回路基板には電気部品のリードなど鋭利な部分がありますので、ボード の表面や部品に直接手を触れないでください。 リモートI/Oターミナル 形 DRT2-ID32B/ID32B-1 形 DRT2-ID32BV/ID32BV-1 形 DRT2-OD32B/OD32B-1 形 DRT2-OD32BV/OD32BV-1 形 DRT2-MD32B/MD32B-1 形 DRT2-MD32BV/MD32BV-1 取扱説明書 オムロン製品をお買いあげいただきありがとうございます。 ご希望どおりの製品かお確かめいただき、この取扱説明書をよく読 んでご理解の上ご使用ください。 なお、この取扱説明書はお読みになった後も、いつも手元において ご使用ください。 この製品を正しく使用していただくために、次のマニュアルを併せ てご覧ください。 ・DeviceNet ユーザーズマニュアル (Man.No.SCCC-308) ・DeviceNet DRT2 シリーズ スレーブマニュアル (Man.No.SBCD-324) 1.設置場所について 次のような環境には設置しないでください。 • 日光が直接当たる場所 • 周囲温度や相対湿度が仕様値の範囲を超える場所 • 腐食性ガス、可燃性ガスのある場所 • ちり、ほこり、塩分、鉄粉が多い場所 • 水、油、薬品などの飛沫がかかる場所 • 温度の変化が急激で結露するような場所 • 本体に直接振動や衝撃が伝わる場所 次のような場所で使用する際は、遮蔽対策を十分に行ってください。 • 静電気などによるノイズが発生する場所 • 強い電界や磁界が生じる場所 • 放射能を被曝する恐れのある場所 • 電源線が近くを通る場所 2.清掃について シンナー類は、装置表面を溶かしたり変色させたりしますので、絶対に使 用しないでください。 3.電源供給について 本体へ接続する通信電源と負荷駆動用の電源は、必ず分離してください。 ■仕様 1632665-2B 安全上のご注意 入力用 :形 DRT2-ID32B/ID32B-1 :形 DRT2-ID32BV/ID32BV-1 出力用 :形 DRT2-OD32B/OD32B-1 :形 DRT2-OD32BV/OD32BV-1 入出力用:形 DRT2-MD32B/MD32B-1 :形 DRT2-MD32BV/MD32BV-1 ●定格 形式 ID32B/ID32B-1 ID32BV/ID32BV-1 OD32B/OD32B-1 OD32BV/OD32BV-1 DC11 ∼ 25V 通信電源 ノードアドレス DeviceNet 設定スイッチ 通信コネクタ DeviceNet 動作表示LED I/O動作表示 LED 基板取付穴 100mA 以下 誤った取り扱いをすると、人が傷害を負ったり、物的 損害の発生が想定される内容を示します。 25 ∼ 85%(結露しないこと) 形式 ×10 I/Oコネクタ ×1 ID32B/ID32BV DC17V 以上 (各入力端子と G 間) OFF 電圧 DC5V 以下 (各入力端子と V 間) DC5V 以下 (各入力端子と G 間) OFF 電流 お願い 以下に示す項目は、安全を確保するために必ず守ってください。 (1) この製品を分解したり、修理、改造をしないでください。 (2) 電源を入れた状態で配線をしないでください。 (3) 製品を落下させたり、異常な振動・衝撃を加えないでください。故障の 原因になります。 (4) 製品の取り付けネジは、規定されたトルクで締めつけてください。 (5) 通信線は指定のケーブルを使用してください。 (6) 通信距離は仕様の範囲内としてください。 (7) 通信ケーブルは、動力線や高圧線から離してください。 (8) ケーブルを無理に曲げたり引っ張りしないでください。 (9) 信号線の断線、瞬時停電による異常信号などに備えて、ご使用者側でフ ェールセーフ対策を施してください。 (10)配線を十分に確認してから通電してください。 (11)端子の極性および I/O 渡し時の電圧仕様を守り、通信路や電源の配線は 正しく行ってください。誤ると故障の原因になります。 (12)電源を入れた状態でコネクタの着脱はしないでください。故障の原因に なります。 (13)本紙記載の仕様に示す電源電圧で使用してください。 (14)電源事情が悪い場所では特に、定格の電圧(や周波数)の電源が供給で きるようにしてご使用ください。 (15)接地された金属に触るなどして人体の静電気を放電させてから、ボード に触れてください。 (16)配線時には、ボードに粉塵や電線の切り屑などが付着しないようにして ください。もし切り屑などがボードに付着すると、回路が短絡する恐れ があります。 (17)運搬や保存時は、LSI、IC などの静電気による破壊防止のため、回路基 板を導電性のもので覆い、保存温度範囲に保ってください。 6.0mA 以下 (DC24V 時) 3.0mA 以上 (DC17V 時 ) (各入力端子と G 間) 1.5ms 以下 1.5ms 以下 ON 遅延時間 OFF 遅延時間 32 点 / コモン 1 回路 回路数 16 点 / コモン 1 回路 16 点 / コモン 1 回路 ●出力部仕様 形式 OD32B/OD32BV 赤 緑 NS 赤 − 黄 点灯 正常 点滅 未設定 点灯 致命的な故障 点滅 軽微な故障 消灯 電源供給なし 点灯 オンライン / 通信接続完 点滅 オンライン / 通信未接続 点灯 致命的な通信異常 点滅 軽微な通信異常 消灯 オフライン / 電源 OFF 状態 点灯 入力信号 ON 状態 消灯 入力信号 OFF 状態 残留電圧 1.2V 以下 (DC0.3A, 出力端子と G 間) 1.2V 以下 (DC0.3A, 出力端子と V 間) 漏れ電流 0.1mA 以下 (DC24V, 出力端子と G 間) 0.1mA 以下 (DC24V, 出力端子と V 間) ON 遅延時間 0.5ms 以下 OFF 遅延時間 回路数 0.3A/ 点 4A/ コモン *1, 3 1.5ms 以下 32 点 / コモン 1 回路 16 点 / コモン 1 回路 32 点 / コモン 1 回路 16 点 / コモン 1 回路 通 V+ 信 CAN H コ ネ DRAIN CAN L ク V− タ 5 4 3 2 1 mch mch mch mch 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 V G 15 14 13 12 11 10 09 08 V G 15 14 13 12 11 10 09 08 mch mch mch mch mch mch mch mch ソレノイドバルブなど 出力 茶 青 (白) (黒) ピン番号 2 1 入力 4 6 mch mch mch mch mch mch mch mch mch mch mch mch ソレノイドバルブなど • 形 DRT2-MD32B/MD32BV(NPN 対応) ソレノイド バルブなど G1 4 3 IN (リミットスイッチなど) 茶青黒 茶 青 (赤) (黒) (白) (白)(黒) ピン番号 2 1 2線式センサ NPN出力3線式センサ (光電スイッチ、近接スイッチなど) V1 24VDC 5 IN 00∼15 2 4 1 3 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 V2 G2 07 06 05 04 03 02 01 00 V1 G1 07 06 05 04 03 02 01 00 OUT OUT OUT OUT OUT OUT OUT OUT IN IN IN IN IN IN IN IN V2 24VDC ピン番号 G2 OUT 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 V2 G2 15 14 13 12 11 10 09 08 V1 G1 15 14 13 12 11 10 09 08 OUT OUT OUT OUT OUT OUT OUT OUT IN I/O電源 24VDC IN IN IN IN IN IN IN I/O電源 24VDC ソレノイド バルブなど 4 G1 3 IN (リミットスイッチなど) 茶青黒 茶 青 (赤) (黒) (白) (白)(黒) ピン番号 2 1 2線式センサ PNP出力3線式センサ (光電スイッチ、近接スイッチなど) V1 24VDC 5 IN 00∼15 2 4 1 3 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 V2 G2 07 06 05 04 03 02 01 00 V1 G1 07 06 05 04 03 02 01 00 OUT OUT OUT OUT OUT OUT OUT OUT IN IN IN IN IN V2 24VDC OUT 00∼15 5 IN 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 V2 G2 15 14 13 12 11 10 09 08 V1 G1 15 14 13 12 11 10 09 08 OUT OUT OUT OUT OUT OUT I/O電源 24VDC フォトカプラ IN ピン番号 G2 OUT IN OUT OUT IN IN IN IN IN IN IN IN I/O電源 24VDC This equipment is suitable for use in Class I, Div. 2, Group A, B, C, D or NonHazardous Location Only. WARNING – Explosion Hazard – Substitution of Components May Impair Suitability For Class I, Div. 2. WARNING – Explosion Hazard – Do not Disconnect Equipment Unless Power Has Been Switched Off Or The Area Is Known To Be Non-Hazardous. 次に示すような条件や環境で使用する場合は、定格、機能に対して余裕を持っ た使い方やフェールセーフなどの安全対策への配慮をいただくとともに、当社 営業担当者までご相談くださるようお願いいたします。 (1) 参照マニュアルに記載のない条件や環境での使用。 (2) 原子力制御・鉄道施設・航空施設・車両・燃焼装置・医療機器・娯楽機 械・安全機器などへの使用。 (3) 人命や財産に大きな影響が予想され、特に安全性が要求される用途への 使用。 mch mch mch mch mch mch カスタマサポートセンタ クイック オムロン 0120-919-066 mch 携帯電話・PHSなどではご利用いただけませんので、 その場合は下記電話番号へおかけください。 ピン番号 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 V G 15 14 13 12 11 10 09 08 V G 15 14 13 12 11 10 09 08 mch mch mch mch mch mch mch mch NPN出力3線式センサ 茶青黒 I/O電源 24VDC (赤) (黒) (白) (光電スイッチ、近接スイッチなど) • 形 DRT2-ID32B-1/ID32BV-1(PNP 対応) 2線式センサ 茶 青 (白) (黒) G 2 ピン番号 2 4 1 3 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 5 7 V G 07 06 05 04 03 02 01 00 V G 07 06 05 04 03 02 01 00 1 m+1ch m+1ch m+1ch m+1ch m+1ch m+1ch m+1ch m+1ch mch mch mch mch mch mch mch mch 入力 ピン番号 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 V G 15 14 13 12 11 10 09 08 V G 15 14 13 12 11 10 09 08 m+1ch m+1ch m+1ch m+1ch m+1ch m+1ch m+1ch m+1ch 入力 I/O電源 24VDC mch 茶青黒 mch mch mch 電話 mch mch mch mch PNP出力3線式センサ (赤) (黒) (白) (光電スイッチ、近接スイッチなど) 055-982-5015(通話料がかかります) 【技術のお問い合わせ時間】 ■営業時間:8:00∼21:00 ■営 業 日:365日 ■上記フリーコール以外のFAシステム機器の技術窓口: 電話 (リミットスイッチなど) V 24VDC フォトカプラ mch 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 I/O電源 24VDC V G 07 06 05 04 03 02 01 00 V G 07 06 05 04 03 02 01 00 • 形 DRT2-□□□32BV(-1) 内 部 フォトカプラ 回 路 9 フォトカプラ 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 m+1ch m+1ch m+1ch m+1ch m+1ch m+1ch m+1ch m+1ch m+1ch m+1ch m+1ch m+1ch m+1ch m+1ch m+1ch m+1ch 3 mch ●お問い合わせ先 2線式センサ G 2 mch インダストリアルオートメーションビジネスカンパニー 3 4 7 mch ピン番号 出力 V+ CAN H DRAIN CAN L V− 内 部 回 路 内 フォトカプラ 部 回 路 V+ CAN H DRAIN CAN L V− 5 mch V G 15 14 13 12 11 10 09 08 V G 15 14 13 12 11 10 09 08 ソレノイド バルブなど (リミットスイッチなど) 5 3 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 • 形 DRT2-MD32B-1/MD32BV-1(PNP 対応) V+ V− CAN H CAN L DRAIN V 24VDC 4 1 6 m+1ch m+1ch m+1ch m+1ch m+1ch m+1ch m+1ch m+1ch ご使用に際してのお願い • 形 DRT2-ID32B/ID32BV(NPN 対応) V+ CAN H DRAIN CAN L V− 4 m+1ch m+1ch m+1ch m+1ch m+1ch m+1ch m+1ch m+1ch ●入出力構成および外部配線 5 ピン番号 2 フォトカプラ DC-DC コンバータ (非絶縁型) 1 17 mch V G 07 06 05 04 03 02 01 00 V G 07 06 05 04 03 02 01 00 1 内 部 フォトカプラ 回 降 路 圧 フォトカプラ 80 mch G 2 00∼15 • 制御盤への取付けはネジ止めで行います。 DIN レール取付けはできません。 • 基板の取付けはスペーサを介して、M4 の取付けネジを使用してください。 締付けトルクは 0.6 ∼ 0.8N・m としてく ださい。 • 取付け方向に制約はありません。 入力 17 7 mch V 24VDC OUT 物理層 ■外形寸法(単位:mm) 80 3 ■配線 *1:外部負荷電流の合計が 4A を超えないよう使用してください。 *2:外部負荷電流の合計が 2A を超えないよう使用してください。 *3:V および G 端子は、1 端子あたり 1A を超えないよう使用してください。 • 形 DRT2-□□□32B(-1) 5 mch I/O電源 24VDC 内 フォトカプラ 部 回 降 路 圧 4-φ4.5またはM4 0.3A/ 点 2A/ コモン *2, 3 出力電流 0.3A/ 点 2A/ コモン *2, 3 4 ●取付け 71.5±0.5 MD32B/MD32BV OD32B-1/OD32BV-1 MD32B-1/MD32BV-1 0.3A/ 点 4A/ コモン *1, 3 3 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 ピン番号 降 圧 5 ●通信回路構成および外部配線 32 点 / コモン 1 回路 1 6 m+1ch m+1ch m+1ch m+1ch m+1ch m+1ch m+1ch m+1ch フォトカプラ V+ CAN H DRAIN CAN L V− 内容 1.0mA 以下 6.0mA 以下 (DC24V 時 ) 3.0mA 以上 (DC17V 時 ) (各入力端子と V 間) 4 内 部 フォトカプラ 回 路 状態 MD32B/MD32BV ID32B-1/ID32BV-1 MD32B-1/MD32BV-1 DC17V 以上 (各入力端子と V 間) ピン番号 2 V G 07 06 05 04 03 02 01 00 V G 07 06 05 04 03 02 01 00 ソレノイド バルブなど LED 表示色 ●取付寸法 ON 電圧 100 通信コネクタの取り付けねじの締めつけは確実に行ってください。 通信コネクタのねじ:0.5 ∼ 0.6N・m 出力 ■取り付け寸法 / 取り付け方法 25 ∼ 85%(結露しないこと) 盤内設置 /M4 ねじ取付け 50g 以下 保存湿度 設置場所・取付け方法 14 注意 1 内 部 フォトカプラ 回 路 V+ CAN H DRAIN CAN L V− • 工場出荷時は 0 になっています。 • 64 以上の設定をすると、ノードアドレ スはコンフィグレータの設定が有効と なります。 − −25 ∼ 65℃ 保存温度 ●警告と注意表示 通電中は、ユニットを分解したり内部に触れたりしないでください。 感電の恐れがあります。 2 基板取付穴 ●表示部 I/O 使用周囲湿度 G 3 ●ロータリースイッチの設定 120mA 以下 −10 ∼ 55℃ 入力電流 警告 4 出力 I/O動作表示 LED I/Oコネクタ(MIL) MS MD32B/MD32B-1 MD32BV/MD32BV-1 V 24VDC 降 圧 5 ソレノイドバルブなど 76±0.5 注意 ソレノイドバルブなど V+ CAN H DRAIN CAN L V− • 形 DRT2-OD32B-1/OD32BV-1(PNP 対応) 緑 110mA 以下 使用周囲温度 100 警告 ノードアドレス 設定スイッチ DeviceNet 動作表示LED 基板取付穴 ●入力部仕様 誤った取り扱いをすると、人が死亡または重傷を負う 可能性が想定される内容を示します。 • 形 DRT2-□□□32BV(-1) m+1ch m+1ch m+1ch m+1ch m+1ch m+1ch m+1ch m+1ch DC20.4 ∼ 26.4V 質量 ●表示の意味 DeviceNet 通信コネクタ 名称 通信電源消費電流 ©OMRON Corporation 2004-2012 All Rights Reserved. • 形 DRT2-□□□32B(-1) 正しい使い方 I/O 電源電圧 オムロン株式会社 • 形 DRT2-OD32B/OD32BV(NPN 対応) ■各部の名称 055-977-6389(通話料がかかります) 【営業のお問い合わせ時間】 ■営業時間:9:00∼12:00/13:00∼17:30(土・日・祝祭日は休業) ■営 業 日:土・日・祝祭日/春期・夏期・年末年始休暇を除く ●FAXによるお問い合わせは下記をご利用ください。 カスタマサポートセンタ お客様相談室 FAX 055-982-5051 ●その他のお問い合わせ先 納期・価格・修理・サンプル・仕様書は貴社のお取引先、 または貴社担当オムロン営業員にご相談ください。 お断りなく仕様などを変更することがありますのでご了承ください。
© Copyright 2024