沖縄県うるま市物件情報 - 太陽光発電で遊休地を土地活用するなら

関係者各位 Dear
I nvest or s
沖縄県うるま市与那城桃原下水1894 太陽光発電事業(96kw)事業計画書
96kw PV Pr oj ect Busi ness Pl an at 1894 Yonashi r ot oubar u Ur uma Ci t y Oki nawa-ken
スマートグリッドホーム株式会社
ht t p: //sghss. co. j p
〒160-0023 東京都新宿区西新宿3-1-4 第2佐山ビル9F TEL(03) 6279-0852
©スマートグリッドホーム㈱ 2005年~
2013年 Al l r i ght s r eser ved. Emai l
addr ess : i nf o@sghss. co. j p
FAX( 03) 6279-0853 1
太陽光発電所建設現場の広域地図 A Wi de Vi ew of t he PV Si t e 沖縄県うるま市与那城桃原下水1894
1894 Yonashi r ot oubar u Ur uma Ci t y Oki nawa-ken
北緯( Lat i t ude ) N26. 360819 東経( Longi t ude) E127. 973678
©スマートグリッドホーム㈱ 2005年~2013年
All rights reserved. Email address :
[email protected]
2
太陽光発電所建設現場の広域地図 A Wi de Vi ew of t he PV Si t e 沖縄県うるま市与那城桃原下水1894
1894 Yonashi r ot oubar u Ur uma Ci t y Oki nawa-ken
北緯( Lat i t ude ) N26. 360819 東経( Longi t ude) E127. 973678
©スマートグリッドホーム㈱ 2005年~2013年
All rights reserved. Email address :
[email protected]
3
周辺位置図と航空写真 Vicinity map and Pr oj ect Si t e Bi r d` s Vi ew
現場は山林:The si t e i s a For est l and.
初期刈払費用は¥50,000程度:The expense for land weeding out is no more than \50,000
賃借可能な土地1, 923㎡
Rentable Land:1,923㎡
借地単価 年間打ち合わせ
買い取り単価は打ち合わせ
Year leasehold unit price will be meeting
Purchase price will be meeting
©スマートグリッドホーム㈱ 2005年~2013年
All rights reserved. Email address :
北緯( Lat i t ude ) N26. 412747 東経( Longi t ude) E127.
813945
[email protected]
4
太陽光発電所建設現場の状況
Pr oj ect Si t e Phot os
©スマートグリッドホーム㈱ 2005年~2013年
All rights reserved. Email address :
[email protected]
5
現場における発電量算定根拠
Verification of the Power Output at the Project Site
©スマートグリッドホーム㈱ 2005年~2013年
All rights reserved. Email address :
[email protected]
6
沖縄県うるま市与那城桃原の現場における年間の発電量算定根拠
http://app7.infoc.nedo.go.jp/cgi-bin/monsola.cgi?p=91166
1
(独)新エネルギー・産業技術総合開発機構(NEDO)の日射データベースによる宮城島と東京の真南、30°傾斜の
場合の月平均日射量の年間平均値は下記の通り。
①うるま市
月平均日射量の年
間平均値
4.14
②東京
①/②
3.73
1.1099
(単位:kWh/㎡・day)
2
よって現場は東京の日射量の110.99%の太陽エネルギー量を有していると言える。
3
一方で東京における1kW当たりの発電量はメーカーが自社製品のカタログに使用する保守的
なデータから1104.75kwh/kwと設定できる。(30°傾斜 真南の場合、パワコン、ケーブルロスも
含む)
カナディアンソーラー 4.0kwの東京における年間発電量は4,419kwhと同社のHPに表記されて
いる。 1KWあたり、1104.75kwhとなる。
http://canadiansolar.co.jp/solar-panel/why-canadian-solar/
従って本候補地における発電量を次のように設定した。(小数点の切り捨て無しで計算)
・真南:30°傾斜の場合:1104.75x(110.99/100)=1226.16kwh/kWと設定した。
4
・真南:20°傾斜の場合:30°の場合と比べて発電量は%減(2%減となる98%掛けの係数は次の次頁の表を参
照) 。 ・メガソーラーの延長ケーブルによるロス=5%として年間の総発電量は下記の通り。
1226.16x(110.99/100)x98%x(100-5)%(=1267.0118kwh/kWp) x40kw=50,680kWh/年間
©スマートグリッドホーム㈱ 2005年~2013年
All rights reserved. Email address :
[email protected]
7
The Verification of the Power Output at the Project Site
1
According to the irradiation database of NEDO(The New Energy Development Organization ), the daily average
irradiation of Uruma, the nearest data point to the Project Site(Miyagi 15km South by East of the Project Site )
and Tokyo ( 30 degree, true south ) is as follows:
① Uruma
2
(Unit:kWh/㎡・day)
②Tokyo
The Daily Average Irradiation
4.14
3.73
(30 Degree True South)
The project site is endowed with an irradiation of 110.99% that of Tokyo.
①/②
1.1099
3
We can safely say that the PV power output in Tokyo per kWp is kWh/kW. This number is derived
from the homepage data offered by Canadian Solar.( Canadian Solar Module produce
4419kwh/kW per 4.0kWp, including module loss, power conditioner loss or cable loss under the
condition of 30 degree true south. )
http://canadiansolar.co.jp/solar-panel/why-canadian-solar/
4
We have concluded that the PV power output at the project site can be derived as follows:
・True South:30°Degree Inclination: 1104.75x(110.99/100)=1226.16kwh/kW
・True South:20°Compared with 30°case, the power output must be 2%less( See the diminishing rate table
in the next page: 98% of 30 degree true south.)
・We assume that the cable loss due to longer wiring of the PV plant is 5%
1226.16x(110.99/100)x98%x(100-5)%(=1267.0118kwh/kWp) x40kw=50,680kWh/year.
©スマートグリッドホーム㈱ 2005年~2013年
All rights reserved. Email address :
[email protected]
8
傾斜角度と方角による発電量の減衰度合い:真南、30°傾斜と比較して
The Diminishing Rate of the PV Power Output by Inclination and Direction vs. True South and 30 degree.
Source: JPEA Japan Photovoltaic Power Association
True South
©スマートグリッドホーム㈱ 2005年~2013年
All rights reserved. Email address :
[email protected]
9
宮城島の日射量情報
Irradiation Data of the Project Site 年間平均Annual Average:4.14kWh/㎡・day
北緯( Lat i t ude ) N26. 412747 東経( Longi t ude) E127. 813945
方位Direction:真南 True South
架台傾斜角度: The Inclination Angle of the Mounting System 30°
©スマートグリッドホーム㈱ 2005年~2013年
http://app7.infoc.nedo.go.jp/cgi-bin/monsola.cgi?p=91166
All rights reserved. Email address :
[email protected]
10
東京の日射量情報 Irradiation Data in Tokyo (出所 Source:NEDO MonSolar )
年間平均 Annual Average:3.73kWh/㎡・day
N 35.6896, E139.7618
方位Direction:真南 True South,架台傾斜角度 The Inclination Angle of the Mounting System 30°
©スマートグリッドホーム㈱ 2005年~2013年
Source: NEDO Monslolar Database http://app7.infoc.nedo.go.jp/cgi-bin/monsola.cgi?p=44132
All rights reserved. Email address :
11
[email protected]
沖縄県うるま市与那城桃原の地震・津波・気温の情報
Information of the earthquake and tsunami, temperature of Uruma 北緯( Latitude )N26.412747 東経( Longitude) E127.813945
©スマートグリッドホーム㈱ 2005年~2013年
http://www.data.jma.go.jp/obd/stats/etrn/select/prefecture00.php?prec_no=36&block_no=47598&year=&month=&day=&view=
All rights reserved. Email address :
[email protected]
12
現場におけるメンテナンス対応
Maintenance support at the Project Site
*自社のメンテナンス会社に依頼
年間メンテナンス詳細別途打合せ
*Depend on the Our company
*Meeting separately annual maintenance details
©スマートグリッドホーム㈱ 2005年~2013年
All rights reserved. Email address :
[email protected]
13
参加費無料の太陽光発電セミナー開催!
利回り最大 15.7%。売電単価 43.2 円のプレミアム物件を、今だけの特別価格で提供いたします。
利回り最大 15.7%のプレミアム物件にご興味はありますか?
残された数少ない 43.2 円案件となります。
ご興味のある方は参加費無料の少人数限定セミナーにお越し下さい。
セミナーのご案内はこちら【先着順】
http://sghss.co.jp/seminar.html
【主催】スマートグリッドホーム株式会社
【フリーダイヤル】0120-836-800
【メールアドレス】[email protected]
【HP】http://sghss.co.jp/